UV test · UVID120Lab UV test
3.0%Median TOPCon power loss after 120 kWh/m² of UVTypical (median) TOPCon power loss after a set lab dose of UV light, 120 kWh/m²[5]
Night drone EL finds UVID; QE quantifies the power each module loses in daylight operation, the figure a warranty claim rests on.Night drone EL finds UVID. Quantified Energy turns those images into the power each module loses in operation, the number a warranty claim needs.
TitleMeasuring Real-World Power Loss of UVID-Affected TOPCon Modules
In brief
Abstract TOPCon made up about 75% of cell production in 2025[4]; UV-induced degradation (UVID) is a major reliability concern for it[5]. UVID-affected cells carry a permanent loss and a recoverable loss that builds up in the dark and recovers in light[1],[2]. Drone electroluminescence (EL) is flown at night and records both; separating them is what allows a warranty claim to rest on the loss in operation rather than on the night state. Quantified Energy instead calculates each module's power loss in daylight operation. Cells are normalized to the 90th percentile of their module, and the dark-cell level is fitted against time after sunset (one project: 9,353 night modules over four nights, flown 0.3 to 5.8 h after sunset; r_sun = 0.529, r_∞ = 0.25, τ = 0.84 h). Dusk and night flights of the same 20 strings (580 modules) calibrate the drop from sunset to night: recovering dark cells regain 0.20 ± 0.05 of the healthy level. Each dark cell is lifted toward its sunset level, tapered for cells near the dark threshold, which are often naturally gray, and reduced for the darkest cells, which recover less. Checked cell by cell against the dusk flight of these 580 modules (one array, one night, one dusk pass), the corrected dark-cell levels are unbiased on average (+0.1%) and within about 6% of the healthy level per cell (RMS 5.7%), against −19.0% for the night image as measured. The corrected image is converted to module power with the degradation-mode EL-to-power method[2]; the loss is reported per module, split into permanent and recoverable parts, and benchmarked to flash I-V on a sample of modules. τ differs from lab kinetics[1] and is measured per project. This paper covers the UVID dark-cell step of QE's warranty-claim workflow; other defects found in the same survey are assessed under the material warranty and are out of scope.
Why
UVID adds a recoverable loss in the dark, and night drone EL records it.
Why · The fleet
PERC led until the move to TOPCon began in mid-2022[1]. By 2025 about 75% of the solar cells made were TOPCon[4], and so were about 95% of the modules shipped by the top-ranked suppliers[6]. TOPCon is expected to stay the main technology for the next decade[4].
PERC led until the shift to TOPCon began in mid-2022[1]. In 2025 TOPCon made up about 75% of crystalline silicon cell production[4] and about 95% of shipments by ranked suppliers[6], and it is expected to remain the leading technology for the next decade[4].
Share of modules shipped · 100 squares = 100%2025 · TOPCon ≈90%
Shipment share: InfoLink 2025 ranking, about 95% TOPCon and 1 to 2% PERC among the top-ranked suppliers[6]. The chart rounds TOPCon down to about 90% to allow for smaller suppliers outside the ranking (QE estimate, not a published figure). Cell production share, about 75% TOPCon, and global shipments: ITRPV[4]. The mid-2022 view is illustrative, with PERC still leading as the move to TOPCon began[1].
Shipment share: InfoLink 2025 ranking, TOPCon about 95% and PERC 1 to 2% of shipments by ranked suppliers[6]. The chart rounds this down to about 90% to allow for suppliers outside the ranking (QE estimate, not a published figure). Cell production share, about 75% TOPCon, and global shipments: ITRPV[4]. The mid-2022 view is illustrative, with PERC dominant as the shift to TOPCon began[1].
Why · The risk
That fleet carries a known risk. UV-induced degradation (UVID) is a power loss caused by the shortest ultraviolet light in sunlight, below 340 nm. Tropical sites receive more of this light, and modules there can show UVID within their first year in the field[1].
UVID is driven by deep UV below 340 nm. Tropical sites receive a higher dose of it and can show UVID within a year of field exposure[1].
UV test · UVID120Lab UV test
3.0%Median TOPCon power loss after 120 kWh/m² of UVTypical (median) TOPCon power loss after a set lab dose of UV light, 120 kWh/m²[5]
Same test · recipe mattersSame test · materials matter
up to14.1%For one bill of materials; 3.6% for another with cells from the same supplierFor one choice of module materials; 3.6% for another built with cells from the same supplier[5]
Field · one year
up to8%Power loss after one year in the field, mainly attributed to UVID; median 2%[5]
Kiwa PVEL 2026 PV Module Reliability Scorecard[5]. Bars share one scale, 0 to 15% power loss.
Why · Two losses
UVID costs a cell power in two ways[1],[2]. The permanent loss stays while the module operates in daylight. The recoverable loss builds up while the module is in the dark and recovers when light returns the next day[1]. A warranty claim must therefore be built on the loss in operation, which is the permanent loss.
UVID-affected cells carry two loss components[1],[2]. The permanent loss, ΔP_perm, remains in the light-recovered state of daylight operation. The recoverable dark-storage loss, ΔP_rec, builds up in the dark and is recovered by illumination the next day[1]. A warranty claim must rest on the loss in operation.
What a claim would see · one module, three states [1]module powerPmax vs 630 W nameplate
Measured in the dark state, the module appears to lose 12.2%; in operation it loses 5.9%[1].
After time in the dark, the module appears to lose 12.2%. In operation, it loses 5.9%[1].
The uncorrected night state roughly doubles the apparent loss · a claim rests on the loss in operation
At most about 37 W lost in operation, not about 77 W · an uncorrected dark reading roughly doubles the loss
Lab EL and flash I-V, SERIS with Quantified Energy[1]. The same TOPCon module, nameplate 630 W, 1 A injection, 15 s exposure; light soaking 1000 Wh/m². The 1 h value after light soaking is taken as the light-recovered state of operation.
Lab data, SERIS with Quantified Energy[1]: EL images and flash power tests of one TOPCon module, nameplate 630 W. After a measured dose of light, 1000 Wh/m², its power 1 h later is taken as its daylight state. The difference from the dark readings is recoverable loss.
20 field modules · each imaged after dark storage and after light soakingeach imaged after time in the dark and after light [2]TOPCon · tropical field exposure
Most of the extra loss seen after time in the dark recovers with lightDark-storage degradation is largely reversible by light soaking[2]
Wide spread of cell damage after time in the dark · a tight group of mildly affected cells after lightBroad, right-skewed after dark storage · narrow peak after light soaking
EL images: [2] Fig. 3, brightness on a log scale. Histogram, re-plotted from [2]: how strongly each cell is degraded, worked out from a single EL image at 6 A of each of the same 20 modules, once after time in the dark and once after light.
EL images: [2] Fig. 3, log intensity scale. Histogram: re-plotted from [2], per-cell degradation severity inferred from a single 6 A EL image of each of the same 20 modules, after dark storage and after light soaking.
Why · Timing
The recoverable loss starts to build up again as soon as a module is back in the dark[1]. A night drone EL image therefore shows the permanent loss plus part of the recoverable loss, and how much depends on the time since sunset. Left uncorrected, it inflates the loss a claim reports.
Dark-storage loss begins as soon as a light-recovered module is in the dark[1]. Night drone EL therefore records the recoverable loss on top of the permanent loss, by an amount that depends on the time since sunset. Left uncorrected, it inflates the loss a claim would report.
Lab · power lossPmax loss after light recovery [1]module dependent
Points: lab values after light recovery[1]; the line only guides the eye. The survey window is indicative.
Points: lab power tests of modules that had recovered in light and were then kept in the dark[1]; the line only guides the eye. The loss keeps growing through the hours of a night survey. The survey window is indicative.
Why · In the field
Night EL is where UVID shows most clearly: in the dark, affected cells stand out from healthy ones. On this project, they kept getting darker after sunset and through the night as the recoverable loss built up[1], while healthy cells barely changed. Because every image carries its time after sunset, the two losses can be separated, and a claim can rest on the loss in operation.Night EL is the most sensitive view of UVID: it records the permanent and the recoverable loss together. Field data from this project show UVID-affected cells darkening after sunset and through the night, consistent with the recoverable loss building up[1], while healthy cells change little. With each image's time after sunset known, the recoverable part can be removed and the loss in operation reported.
Same module, two flights5 A

healthy cells, night brightness compared with dusk; no larger than the normal difference between two flightshealthy cells, EL ratio night ÷ dusk; within flight-to-flight noise
dark cells that recover, drop in brightness from dusk to night, as a share of the module's healthy level (about one fifth, give or take 0.05)recovering dark cells, change in r_i from dusk to night, in units of EL_ref, ± 0.05
Field data, this project: the same 20 strings flown 7 to 17 min after sunset and again 2.5 to 2.7 h after sunset; 580 modules compared cell by cell at the same current, 5 A. Brightness is measured against each module's healthy level, the brightness of its own healthy cells. Healthy cells hardly changed. Most dark cells were about one fifth of the healthy level brighter at dusk than at night. The darkest cells changed less, and many cells only just below the dark-cell threshold did not change at all: they are naturally gray cells that never darkened.
Field data, this project: the same 20 strings flown 7 to 17 min after sunset and again 2.5 to 2.7 h after sunset; 580 modules compared cell by cell at 5 A. Levels are relative to each module's healthy level, EL_ref. The −0.20 applies to dark cells that recover; the darkest cells recover less, and many cells near the dark threshold are naturally gray and do not recover.
Modules with very dark cells · below-15% classdarkest classsame images, same thresholds
Whole project
Dusk check · 580 modules
Counted on the night images, very dark cells appear on 2,396 modules. Corrected to daylight, they remain on 12. The dusk flight confirms this: on the 580 modules flown again at dusk, 101 modules showed very dark cells at night, only 5 at dusk and none after correction.Very dark cells appear on 2,396 modules at night but on 12 after correction; the dusk flight confirms the drop (101 modules at night, 5 at dusk, 0 corrected, on the same 580 modules).
Field data, this project. Night and dusk counts are measured; the corrected counts are modeled. The very dark cells that remain in daylight are permanently inactive cells, not the recoverable loss.
Field data, this project. Counts on cell levels with the same thresholds for all images; night and dusk counts measured, corrected counts modeled. Very dark cells that remain in daylight are permanently inactive cells.
A claim needs the loss in daylight operation, so the night image needs correcting.A claim needs the loss in operation, so the night image must be corrected.
How
Six steps from a night flight to power loss per module.
How · Steps 1 and 2
The correction starts with how the plant is flown. The drone flies from dusk into the night and images each module once, so different modules are imaged at different times after sunset. Together, they show how dark cells change through the night. Each cell is measured against its own module's healthy cells, so one image per module is enough. Only a small sample, 20 strings, is flown a second time, just after sunset, to pin down the start of the curve.Modules imaged at different times after sunset sample the darkening curve cross-sectionally. Each cell is normalized to its own module's healthy level, so the survey images each module once; a sample of 20 strings is also flown just after sunset to calibrate the early part of the curve.
How · Step 3
Next, the dark cells are grouped by flight time, in steps of 15 minutes after sunset. The typical dark cell in each group gives one point. One smooth curve through these points is the project's darkening curve. Its darkening time constant, τ, sets how fast dark cells darken: the shorter τ, the faster.The median dark cell in each 15-minute bin of t, fitted with one empirical exponential for this project. Its time constant τ sets the speed of darkening.
Step 3 · Bin, take the median, fit τGroup, take the typical cell, fit τ
τ is fitted per project
Points are illustrative. The curve is fitted to field data, this project: 9,353 night modules over four nights, flown 0.3 to 5.8 h after sunset, and the same 20 strings (580 modules) flown at dusk and at night. A typical dark cell sits at 0.53 of the healthy level at sunset and falls toward 0.25 during the survey hours, with τ of 0.84 h. These values apply to this project only, and dark cells keep darkening through the night. An earlier curve fitted to the night flights alone left corrected cells 10% too dark, because the night flights cannot show how far the cells fell in the first hour after sunset. That is why a few strings are also flown at dusk. An earlier fit on night data alone under-corrected, leaving cells 10% too dark; paired dusk strings fix the sunset level.
How · Step 4
The darkening curve sets how far to brighten the dark cells, as a share of the module's healthy level. Healthy cells are left as they are. A clearly dark cell gets the full amount read from the curve. Gray cells, between 0.35 and 0.75 of the healthy level at night, get less the lighter they are, because many of them are naturally gray and never darkened. The very darkest cells also get less, because they recover less. Cracked cells and cells that received no current are kept as measured.Healthy cells are unchanged. Each dark cell is lifted by the curve amount r(t′) − r(T), in units of its module's healthy level EL_ref: in full for clearly dark cells, tapered between night levels 0.35 and 0.75, and reduced for the darkest cells. Cracked cells and cells without current injection keep their measured level.
Step 4 · Lift dark cells along the curve
EL level · fraction of the healthy levelBrightness · share of the module's healthy level
Field data, this project: on the same 20 strings (580 modules) flown at night and again at dusk, recovering dark cells regained 0.20 ± 0.05 of the healthy level. The share of cells that recover falls from about 99% at night levels of 0.15 to 0.35 to 69% at 0.45 to 0.50 and 26% at 0.60 to 0.65, and the darkest cells regained only 0.14 to 0.16. Example cells are illustrative, with a full lift of 0.20.
Field data, this project: the same 20 strings (580 modules) were flown at night and again at dusk. Dark cells that recovered were 0.20 of the healthy level brighter at dusk, give or take 0.05. Almost all cells at night levels of 0.15 to 0.35 recovered, but only 69% at 0.45 to 0.50 and 26% at 0.60 to 0.65, and the darkest cells recovered only 0.14 to 0.16. So each dark cell gets an amount, not a multiple, weighted by how dark it was at night. Example cells are illustrative, with a full lift of 0.20.
How · Step 5
Applied to every dark cell with the rule of Step 4, the lift moves the whole night image back along the darkening curve to sunset. That is the daylight state, the state a module is in after time in the light. The corrected image, called daylight-equivalent EL, removes the recoverable loss that built up in the dark and keeps the permanent loss. Step 6 turns it into module power. On this project, a typical dark cell sits at 0.53 of its module's healthy level at sunset and falls toward 0.25 during the night survey. Moving the image to the time of the dusk flight, instead of to sunset, allows a direct check against the dusk image.Each night image is lifted with Eq. (3) along this project's curve to t′ = 0, the light-recovered state at sunset. The result, daylight-equivalent EL, removes the recoverable night loss and keeps the permanent loss; it is the input to the power calculation in Step 6. A typical dark cell sits at r_sun = 0.53 of its module's healthy level at sunset and falls toward r_∞ = 0.25 during the night survey; other target times serve the dusk-flight check.
Curve fitted on field data, this project. Measured: the night image, 2.67 h (160 min) after sunset, and the dusk image, 0.27 h (16 min) after sunset, both at 5 A. Modeled: every other time, moved from the night image along the curve with the lift rule of Step 4. Moved to the dusk flight's own time, the corrected dark cells agree with the dusk images of 580 modules without bias, within about 6% of the healthy level per cell.Curve: Eq. (2), fitted on field data, this project. Measured: night EL at T = 2.67 h and dusk EL at 0.27 h after sunset, both at 5 A. Modeled: every other time, lifted from the night image with Eq. (3). Simulated to the dusk flight time, dark cells on 580 paired modules show bias +0.1% and RMS 5.7% of the bright level.
How · Step 6
Per-cell severity from the corrected EL image feeds a circuit model of the module, giving Pmax at STC[2]. Taken in the daylight state, it estimates the module's power in operation, to compare with the warranted minimum power.
The last step turns the corrected image into watts. The image shows how strongly each cell is affected. A circuit model of the module combines the cells into the module's maximum power under standard test conditions[2]. Because the image is in the daylight state, the result estimates the module's power in operation, the value to compare with the warranted minimum power.
Step 6 · EL to module power, one lab module[1]
Shown: 1 h after light soaking · light-recovered, daylight state
a · EL image
Measured · 1 h after light
Field: night EL corrected to the daylight state, t′ = 0, Eq. (3).
In the field: the night image, corrected to the daylight state in Step 5.
b · Per-cell severityb · How affected each cell is
Degradation mode: J01-dominated recombination[2].
Each cell is scored assuming UVID acts through one type of damage: extra charge losses inside the cell[2].
c · Module Pmax at STCc · Module maximum power
593W−5.9% vs 630 W
Cells in a module circuit model at 1 Sun[2]. Value shown: flash I-V[1].
The cells are combined in a circuit model of the module under full sunlight[2]. Value shown: measured with a lab flash tester[1].
Lab data[1], one 630 W TOPCon module, EL at 1 A; Pmax from flash I-V. The dark-storage image stands in for an uncorrected night image, the light-recovered image for the corrected daylight state. Severity shading and I-V curve are illustrative, not model output.
Lab data[1], one 630 W TOPCon module, EL at 1 A; power measured with a lab flash tester. The image after dark storage stands in for an uncorrected night image, and the image after light recovery for the corrected daylight state. The cell shading and the power curve are illustrative, not model output.
Same module, three states[1]
Pmax at STC · WMaximum power at standard test conditions · W
Claim basis: at most ≈37 W lost in operation, not ≈77 W.Claim basis: at most about 37 W lost in operation, not about 77 W.
Lab data[1], one module; Pmax at STC from flash I-V. The 593 W reading was taken 1 h after recovery, with the module already back in the dark, so the loss in operation is at most about 37 W. The 40 W between 593 W and 553 W is recoverable in light.
Lab data[1], one module, measured with a lab flash tester. The 593 W reading (−5.9%) was taken 1 h after light exposure, with the module already back in the dark, so the loss in operation is at most about 37 W. The other 40 W, down to 553 W (−12.2%), is recoverable loss.
EL-to-power vs flash I-VHow accurate is power from EL?[2]
20 TOPCon modules · one 6 A EL image each, about 40% of Isc
20 TOPCon modules · power from one EL image each, against the lab flash test · about 1% typical error
Re-plotted from [2], Fig. 5. Statistics for the verification set[2].
Re-plotted from [2]. Each point is one module; the closer it sits to the dashed line, the closer power from EL is to the lab measurement. On the modules used to check the model, the typical error is about 1% (1.1%, about 6.5 W on a 593 W module)[2].
Result
A claim-ready power loss, checked in the field and in the lab.
Result · Claim-ready report
For each module, the report gives its power in daylight operation, with permanent and recoverable loss shown separately, ready to set against the warranted minimum power in its module warranty.All six steps lead to one report. For each module, it gives the power in operation, with the permanent and recoverable loss shown separately, ready to compare with the warranted minimum power in the module warranty.
One string · power in operation vs warranted minimum
Module Pmax · illustrative scaleModule power · illustrative scale
Illustrative values, not project results. The vertical gap is the recoverable loss at survey time.Illustrative values, not project results. The vertical gap is the recoverable loss at survey time. Judged on the raw night image, more modules fall below the line than in operation.
Module report card
Illustrative584W
Power in operation · daylight state, t′ = 0corrected to the daylight state · −7.3% vs nameplate
Below the warranted minimum in operationClaim candidate
Report · what each project report includes
Only UVID dark cells are treated here; other defects are assessed under the material warranty. Warranty terms and claim procedures differ by manufacturer and contract, so the report supplies technical evidence and does not decide the claim outcome.
Result · Validation
The correction is checked in two ways. In the field, the same 20 strings are flown at night and again just after sunset. Each night image is moved back along the darkening curve to the time of the dusk flight and compared, cell by cell, with the dusk image of the same module. On 580 modules, the corrected image shows no bias and agrees within about 6% of the healthy level per cell. In the lab, EL images taken hours into the dark are corrected back to the daylight state[1]. Correcting a field image to the daylight state is the same step, taken all the way back to sunset.Field: 20 strings (580 modules) flown at night and again at dusk; each night image is shifted with Eq. (3) to the dusk flight's own time and compared cell by cell with the measured dusk image. Lab: EL images back-calculated to the light-recovered state[1]. Daylight-equivalent EL is the same step with t′ = 0.
Accuracy against a dusk flight · 580 modules
Checked against a real dusk flight, the corrected image is unbiased and within about 6% per cell.
Simulated to the dusk flight's time, dark cells show a bias of +0.1% and an RMS error of 5.7% of the bright level, against −19.0% for the night EL as measured.
1How far dark cells are from the dusk imageBias against the dusk EL, % of bright level
2Modules with very dark cells, of 580Modules with 15% class cells, of 580
3Where the remaining spread comes fromError budget of the 5.7% scatter
Two flights, same healthy cells. The same bright cells differ by this much between the dusk and the night flight (camera, exposure, alignment).Flight to flight. Same bright cells, two flights: camera, exposure and alignment.
Cells that do not recover. They are as dark at dusk as at night: permanently inactive cells and likely soiling along the module frame. There are 117 such cells on 33 modules, and the correction lifts them anyway. Without them, the spread falls from 5.7% to 4.4%.Non-recovering cells (117 cells on 33 modules): permanently inactive cells and likely edge soiling, lifted anyway. Without them: bias −0.7%, scatter 4.4%.
Recovery differs cell by cell. Recovering dark cells regain 0.20 of the healthy level, give or take 0.05, varying from module to module (5.6%) and within a module (3.5%).Individual recovery. Spread between modules 5.6%, within a module 3.5%. Not reducible from a night image.
In the field · One module, night scaled to dusk



Measured · dusk, 16 min
Example module, field data, this project: night image 160 min and dusk image 16 min after sunset, both at 5 A. For these two times the darkening curve predicts that a typical dark cell is 0.19 of the healthy level brighter at dusk. Across the 20 strings (580 modules) flown at both times, recovering dark cells were 0.20 brighter at dusk, give or take 0.05.
Example module, field data, this project: night EL at T = 2.67 h, dusk EL at 0.27 h, both at 5 A. Curve change between the two times 0.19 of the bright level (modeled); recovering dark cells on the 580 paired modules: 0.20 ± 0.05 (measured).
In the lab · power read from ELEL-derived Pmax[1],[2]
Lab vs field · Darkening time constant
The lab curve has a fast part close to the field τ and a slow part that keeps darkening through the night.
In the lab, darkening has a fast part, about as quick as in the field, and a slow part that keeps darkening through the night.
Longer bar, slower darkening. Field: τ fitted on this project's own night flights. Lab: QE analysis of one module from the dark-storage data set of[1], recovered with UV light and then kept 0 to 21 h in the dark. Its darkening is best described in two parts: a fast one, τ of about 1.3 h, close to the field value, and a slow one, about 13 h, that continues through the night. Fitted as a single part, the lab data give about 10 h, and that figure grows the longer the data run. During a night survey, the project curve mainly follows the fast part. Indicative: one module, from another site. Darkening speed depends on module type, history, temperature and light, which is why τ is measured on each project and checked with a dusk flight.
Longer bar, slower darkening. Field τ: Eq. (2), field data, this project. Lab τ: QE analysis of one module from the dark-storage data set of[1] (UVA recovery, 0 to 21 h in the dark, EL-derived Pmax), fitted with two exponential components. A single-component fit gives τ ≈ 10 h, and its value grows with the fit window. Indicative: one module, from another site.
Result · Evidence
Each part of the result is tested in the lab. Power from EL is checked against power measured in the lab. The need to correct night EL comes from lab power tests during dark storage. The correction itself is checked by taking lab images back to the daylight state, and in the field against a dusk flight of the same modules.Each part of the power-loss figure traces to lab measurement: the EL-to-power conversion against flash I-V, the need to correct night EL from dark-storage I-V checkpoints, and the correction itself from back-calculation of lab images and, in the field, from a cell-by-cell comparison with a dusk flight.
Step 6 · powerSingle EL image to module power, 20 TOPCon modules
R² shows how closely power from EL matches power measured in the lab (1 is a perfect match); typical error about 1%, one EL image per modulePmax R² 0.910, RMSE 1.1%, verification set, one 6 A EL image per module · Re-plotted from [2]
[2]IEEE JPV, in revisionWhy correctPower lost within 6 h in the darkPmax lost within 6 h of dark storage
Lab power tests on UVID-affected TOPCon modules kept in the dark after light recovery; about 1% after the first hour, at a rate that differs from module to moduleUVID TOPCon after light recovery, flash I-V checkpoints; about 1% after 1 h, module dependent
[1]EU PVSEC 2026Step 5 · correctionPower from EL taken in the dark, corrected back to the daylight stateEL-derived Pmax back-calculated to t = 0, the light-recovered state
matches within about 2 W, for images taken up to 21 h in the darkagrees within ≈2 W for images taken up to 21 h in the dark
QE analysis of the [1] datasetStep 5 · field checkCorrected dark cells against a real dusk flight, 580 modulesSimulated dark-cell levels against a dusk flight, 580 modules
No bias on average, and about 6% of the healthy level per cell; read directly from the night image, the same cells are 19% of the healthy level too darkbias +0.1%, RMS 5.7% of the bright level on 2,328 dark cells; night EL as measured −19.0%
Field data, this projectStatus: reference [2] is in revision and reference [1] is a conference presentation, so these results are not yet fully peer reviewed.
Quantified Energy is a spin-off of the Solar Energy Research Institute of Singapore (SERIS) at the National University of Singapore.
Technical · Methods and limitations
The data sets, notation, the model behind Steps 1 to 6, fitted parameters, limitations, and the claim workflow on a new project. Field values come from one project and do not transfer to others.
| Data set | Size and conditions | Used for | Label |
|---|---|---|---|
| Project field data set | 9,353 night modules · four nights · flown 0.3 to 5.8 h after sunset · 5 A drive current · each module imaged once | Fit of Eq. (2): pins r_∞; within-array trend after 1.5 h, about −0.004 per hour, consistent with the curve | Field data, this project |
| Paired-flight subset | 20 strings · 580 modules · one array · imaged 7 to 17 min after sunset and again 2.5 to 2.7 h after sunset, same night · 5 A | Drop from sunset to night (pins r_sun): recovering dark cells regain 0.20 ± 0.05 of EL_ref; taper band and depth factor of Eq. (3); cell-by-cell accuracy check of the correction | Field data, this project |
| Lab data [1] | UVID TOPCon modules · light recovery, then dark storage · flash I-V and EL checkpoints | Dark-storage kinetics (≈1% Pmax loss after 1 h, 2.5% after 6 h, module dependent); QE analysis: EL-derived Pmax back-calculated to t = 0, lab refit of τ | Lab data [1] · QE analysis |
| Lab data [2] | 20 TOPCon modules · at least 6 months tropical field exposure · 6 A EL (≈40% of Isc) · dark storage and light soaking | Step 6: EL-to-power conversion from a single EL image (degradation-mode analysis); verification set Pmax R² 0.910, RMSE 1.1%; Voc R² 0.929, RMSE 0.6% | Lab data [2] |
| r_sun | 0.529 | Dark-cell level at sunset, the light-recovered state; r(t) for t ≤ 0 |
| r_∞ | 0.25 | Level approached within the survey window; cells keep darkening through the night, so this is not an end point |
| τ | 0.84 h | Time constant of darkening after sunset; specific to this project |
| taper | 0.35 / 0.75 | Night levels at which the lift starts to fall below full and reaches zero; given at T = 2.6 h, moved with the curve for other T |
| w_depth | 0.62 | Lift factor at r_i ≤ 0.10, rising linearly to 1 at r_i = 0.20; given at T = 2.6 h |
Field data, this project: 9,353 night modules over four nights, and 20 paired strings (580 modules) flown at dusk and at night. Levels in units of EL_ref. The taper band and the depth factor were fitted on the paired cells; the depth factor was cross-validated between odd and even strings (test RMS 0.4 to 0.5 points better). An earlier curve fitted on night data alone (r_sun 0.436, r_∞ 0.314, τ 0.72 h) lifted dark cells by only 0.09 and left them about 10% too dark. Parameter uncertainties and goodness-of-fit statistics are not reported here. If a later survey on this project starts late, its data constrain only r_∞, and r_sun and τ from this fit can serve as priors; they should not be transferred to other projects.
Sensitivity to τ
IllustrativeOn the 580 paired modules, both images are reduced to their 144 cell averages and normalized to the module's EL_ref. Each night image is lifted with Eq. (3) to the dusk flight's own recording time and compared cell by cell with the dusk image. Cells are classed on the night EL. Values in % of EL_ref; field data, this project.
| Cells (night EL class) | Cells | Bias, corrected | Scatter / RMS, corrected | Bias, night EL as measured |
|---|---|---|---|---|
| Dark, 50% and 15% classes | 2,328 | +0.1% | 5.7% / 5.7% | −19.0% |
| 15% class only | 371 | 0.0% | 5.8% / 5.8% | −15.1% |
| All cells | 83,520 | −0.3% | 2.2% / 2.2% | −1.0% |
Quantified Energy
Quantified Energy gives asset owners and their advisers the power each module loses in operation, measured at fleet scale and traceable to the lab.
The figure a warranty or insurance claim rests on, compared with nameplate and the warranted minimum power in the module’s warranty.
Ready to compare with nameplate and with the warranted minimum power, in a warranty or insurance claim.
Recoverable night loss separated from the permanent UVID loss, with τ measured per project. On one project, modules with 15% class cells fell from 2,396 on the night EL to 12 after correction to daylight (modeled).
The recoverable loss, which builds up at night and recovers in daylight, is separated from the permanent loss. The darkening curve and its τ are measured on each project. On one project, 2,396 modules showed very dark cells in the raw night images, but only 12 after correction to the daylight state (modeled).
Benchmarked to flash I-V on a sample of modules; EL-to-power method[2], dark-storage work with SERIS[1], quantitative EL since 2018[3].
Checked against power measured in the lab on a sample of modules; built on a published EL-to-power method[2], dark-storage work with SERIS[1] and quantitative EL since 2018[3].
Warranty terms differ by manufacturer. The report supplies the measured loss for comparison with the warranted minimum power; it is not legal advice or a prediction of a claim outcome.
Fly once from dusk into the night. Get the loss in operation.
Talk to usLab data: SERIS with Quantified Energy. Field data: Quantified Energy drone EL surveys, 2026.