White paper · Lifecycle series, part one · 2024

Solar cell cracks, and what insurers now ask for.

After a hailstorm, a module can look fine and still be cracked inside. Drone EL reveals cell cracks down to microcracks, fast enough for a whole plant, and provides the cell-level evidence that insurers increasingly require.Cell cracks drive degradation and are increasingly decisive in insurance claims after extreme weather. Autonomous drone EL mapping detects cracks at cell level across utility-scale plants, supporting a three-phase post-disaster workflow and a pre-event baseline for insurability.

TitleEnhancing Solar PV Lifecycle Asset Management through Autonomous Drone EL Mapping – Part One: Addressing Solar Cell Cracks and Insurance Considerations

Quantified Energy, Singapore · with Roderick Rennison, SVP Global Energy Services, RimkusPart one of a three-part series · Read part two →

One module after hail · two ways to lookDaylight photo

Hail hits the module.

Schematic. Field EL images further down are by Quantified Energy.

In brief

  • A plant that loses more than about 0.8% of its output a year earns less than planned. Module defects, including cell cracks, are a major factor, and many cracks cannot be seen by eye or by thermal camera.
  • EL imaging makes cells glow and shows cracks inside them. Done by hand it covers under 500 modules a night. A QE drone covers up to 15,000.
  • Hail and storm losses are rising, and insurers now ask for crack evidence at cell level. A three-phase check after a storm (drone photos, sample EL, full EL) supports the claim and the rebuild.
  • Without an EL record from before the storm, small cracks cannot be blamed on the storm, and may not be covered.

Abstract Annual degradation above 0.8% erodes LCOE; the NREL median is 0.75%/yr. Cell cracks, classified by Köntges as type A, B or C, are among the main defects, and types A and B may not appear in IR. Manual EL is limited to under 500 modules per night, and PL and UVF need light sources too heavy for drones. Autonomous drone EL with an onboard SWIR camera, AI defect detection trained on millions of EL images and EL-based power loss estimation inspects up to 15,000 modules per night. After extreme weather we propose drone visual mapping, sample EL per ISO 2859-⁠1, then full-scale EL against insurer criteria. A pre-event EL baseline is needed to attribute minor cracks to the event.

Cracks

Degradation sets the return. Cracks are where it starts.

Cracks · The return

Every tenth of a percent counts.

Plants lose a little output each year. The median for US plants is 0.75% a year (NREL). Drag the slider: a faster rate takes years of income off a 25-year plant.

LCOE divides lifetime cost by lifetime energy, so the degradation rate is a direct lever on returns. Systems should stay below 0.8%/yr over 25 years; the NREL median across US plants is 0.75%/yr (P50), with a long tail of faster-degrading systems.

25-year output · drag the rate0.75%/yr · 91% of ideal lifetime energy
0.75%/yr

median degradation rate of US PV plants (NREL, P50).

<0.8%/yr

the level a plant should stay under over 25 years to protect its return.

148 sites

in 16 countries: a CEA survey reports an increase in PV module defects.

Cracks · Where damage comes from

Six sources of module damage.

Heat, factory faults, rough handling, poor design, skipped maintenance and storms. Each one weakens modules, and the plant is only as strong as its weakest modules.

Thermal cycling and humidity stress solder and encapsulant; manufacturing defects include microcracks and cold solder; poor installation and transport cause mechanical stress; inappropriate tracker and mounting design adds vibration; inadequate O&M leads to soiling and unaddressed downtime; extreme weather (wind, hail, wildfire) breaks glass and cells.

Cracks · What EL sees

Make the cells glow, and defects go dark.

Send current into the module at night and each cell gives off a faint glow that a special camera can see. Healthy areas are bright. Cracks, broken contacts and dead cells show up dark.

EL applies a forward current so that cells emit near-infrared luminescence, captured with a sensitive camera. Emission scales with local cell quality, so defective regions appear dark against healthy cells. EL is standard in module production and is now practical in the field.

Field EL gallery · tap a defectCell cracks
EL close-up of cells with diagonal crack lines
Cracks show as thin dark lines. Some still let current through.

Field EL images by Quantified Energy.

Cracks · Three types

Thermal cameras can miss early cracks.

A crack can leave the cell fully working, cut part of it off, or cut a piece off completely. Usually only the last one shows in a thermal image. EL shows all three.

Köntges et al. classify cracks as type A (no disconnection), type B (partial disconnection, reduced conduction) and type C (complete disconnection of a cell area). Type C creates hotspots visible in IR; types A and B often do not, yet may propagate over time.

One cell, three cracks · tap a typeType A · no disconnection

Found by ELYes

Found by IRUsually not

Field study · FZ Jülich, Progress in EnergyShare of modules with damage found

The authors recommend combining EL and PL with drone IR.

Drone EL

From one module at a time to a whole plant in a night.

Drone EL · Throughput

Up to thirty times more modules per night.

EL by hand means a crew moving a camera module by module, which is impractical for utility-scale plants. QE's drones fly the plant by themselves.

Manual EL covers under 500 modules per night. PL and UVF need no electrical connection, but the light source is too heavy and power-hungry for drones. QE's drone EL uses an onboard SWIR camera and PC, autonomous flight and string-level current injection.

One night shift · modules inspectedNight shift

Drone EL · The system

Fly, image, analyze, decide.

Established in 2019 by experts from the Solar Energy Research Institute of Singapore (SERIS) at NUS, Quantified Energy developed the full chain: the drone kit, the flight software, the AI that reads the images, and a dashboard of the whole plant.

Custom-built hardware with an onboard SWIR camera and PC; autonomous flight that optimizes imaging parameters; AI trained on millions of field EL images for defect detection and categorization; EL-based power loss estimation; and a digital twin dashboard for filtering, sorting and reporting.

Drone EL · Across the lifecycle

Six moments to look inside.

From handover to repowering, each milestone is a decision about money. Tap a milestone.

COD acceptance

Find installation faults and set a baseline for the plant.

Insurance

Storms are getting costlier. Insurers want cell-level proof.

Insurance · The trend

One hailstorm, 400,000 panels.

One hailstorm in Texas destroyed over 400,000 panels at a single site. Insurance prices then rose sharply, and insurers asked for better proof of damage.

Munich Re reported USD 270 billion in natural disaster losses in 2022. A Texas hail event caused about USD 150 million in insured losses at one site, the largest weather-related loss for a single project on record (pv magazine). Premiums rose by up to 400% in the following 18 months, with stricter terms and requests for cell-level crack evidence.

$0B

natural disaster losses worldwide in 2022 (Munich Re).

0+

panels destroyed at one Texas site by a single hailstorm.

$0M

insured loss from that event, the largest for a single project on record.

+0%

rise in premiums within 18 months.

Insurance · Design choices

Tilt away from hail, or thicken the glass.

Trackers can turn steeply when hail comes, so stones hit at a glancing angle. But that exposes them to wind. Thicker glass resists hail better, at more weight and cost.

Hail stow to about 75° reduces impact energy normal to the glass but increases wind load during convective storms, and tracker wind failures have also damaged modules. Comparative ice ball testing (RETC) shows thicker glass tolerates higher impact energy before breakage. A potential USD 20 billion investment could develop 36 GW of PV in Texas over five years.

Tracker angle · dragFlat · full hail impact
Hail impact on glass
Wind load

Schematic trends, not design values.

Insurance · After the storm

Three phases, from first count to final claim.

First, count what is clearly broken from the air. Then sample with EL to decide which blocks to rebuild. Finally, EL-map all affected and rebuilt blocks for the claim and the new baseline.

Phase one: drone visual mapping with AI to quantify visibly broken modules and open the claim; for very large sites, fixed-wing or manned aircraft at about 500 m. Minor edge cracks in the glass can be missed and are captured later by EL. Phase two: sample EL per ISO 2859-⁠1 to decide, block by block, whether to repair or rebuild. Phase three: full-scale EL to document all damage against insurer criteria and set the post-recovery baseline.

100 MW plant after hail · tap a phasePhase 1 · drone visual

Drone photos and AI count the visibly broken modules and open the claim. Small cracks are missed.

Phase three in the field · drone EL after a hailstormZoom: block, module, cell
Drone EL images of a plant after a hailstorm, zooming from rows of modules to single modules with cracked cells detected automatically

Every module imaged; cracked cells detected and categorized automatically. Field EL by Quantified Energy.

Insurance · Sampling

625 modules to judge 150,000.

A standard sampling table says how many modules to test in each block. Test them in an accredited lab, and the result informs whether a block is kept or rebuilt.

Each block is a lot under ISO 2859-⁠1. The lot size and inspection level give a code letter and sample size; samples go to an ISO/IEC 17025 laboratory, or are imaged on site if the insurer and owner agree. A failing block may be re-tested at General Inspection Level II before a rebuild decision.

Sample size · example from the paper100 MW · 150,000 modules
125

modules per block · code K

625

modules in total · 0.42% of the plant

Implies about 667 W per module (100 MW / 150,000 modules), as in the paper's example. Code letters and sample sizes follow ISO 2859-⁠1 general inspection levels I and II. Verify against the current edition before contractual use.

Insurance · Rebuilding

New modules shine brighter.

Blocks that pass are repaired: damaged modules are bypassed or swapped. New and old modules then sit side by side, and EL tells them apart, which documents the mix for future claims.

Gaps are filled with matching new modules, relocated modules from a rebuilt block, or bypassed. Mixing new and aged modules can add electrical mismatch and mechanical fit issues on trackers. In EL, new modules emit more strongly than aged ones, so the map documents the position of every replacement for future claims and O&M.

Drone EL map · after the rebuildBright: new · dimmer: original
Drone EL map of rows of modules: scattered bright modules are new replacements among dimmer original modules

Field EL map by Quantified Energy.

Insurance · The claim

The rule decides what counts as damaged.

Insurers set a threshold for a "damaged" module. Some used to accept more than 3 cracked cells. Some now ask for more than a quarter of the cells. Switch the rule and watch the count change.

AI detects and counts cracked cells per module, so any policy criterion can be applied to the full EL dataset. Criteria vary by insurer: historically more than 3 cracked cells; some now require more than 25% of cells cracked. The dashboard classifies each module by the agreed criterion.

Same plant, two rules · switch42 of 192 modules qualify

Simulated plant. Colors follow QE's dashboard: no cracks, up to 3 cracks, more than 3 cracks, shattered.

Insurance · The baseline

Without a "before", small cracks are hard to claim.

Both modules below have cracks after a severe hailstorm. Without an earlier EL image, it cannot be shown that the small cracks came from the storm. Only clear hail patterns were accepted.

Dendritic cracks and dark areas typical of impact qualified under the policy. Minor cracks could have come from manufacturing, installation or operation, so without a pre-event baseline they could not be attributed to the hail. A baseline at COD, and after any rebuild, provides the evidence to attribute later damage.

After a severe hailstorm · switchNo baseline
EL image of a module after a severe hailstorm with many cracked cells
After hail · module 1
EL image of a second module after the same hailstorm with cracked cells
After hail · module 2

Takeaway Set an EL baseline at COD, before the defects liability period ends, and after any rebuild. Part two covers the baseline in detail →

Sources and standards

  1. [1]NREL, "How extreme weather and system aging affect the US photovoltaic fleet," 2024. nrel.gov
  2. [2]M. Köntges et al., "Review of failures of photovoltaic modules," IEA-PVPS T13-01:2014. Crack types A, B and C.
  3. [3]C. Buerhop et al., FZ Jülich, "Infrared imaging of photovoltaic modules: a review of the state of the art and future challenges facing gigawatt photovoltaic power stations," Progress in Energy.
  4. [4]Munich Re, natural disaster figures 2022. munichre.com
  5. [5]RETC, "Module glass impacts hail resiliency." retc-ca.com
  6. [6]Oliver et al., outdoor luminescence imaging review, Progress in Energy. doi:10.1088/2516-1083/ac9a33
  7. [7]Engineering News, "Rapid advancement in quality testing for large PV plants," March 12, 2024. engineeringnews.co.za
  8. [8]pv magazine, "Storm season has the US solar industry looking to protect assets from costly hail damage." pv-magazine.com
  9. [9]ISO 2859-⁠1, "Sampling procedures for inspection by attributes. Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection."
  10. [10]ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories."

Authors: Quantified Energy Labs, Singapore, with Roderick Rennison, SVP Global Energy Services, Rimkus. Field data: Quantified Energy drone EL surveys. Series: part one (this paper) · part two: degradation monitoring from day one.

Make every PV module count throughout its lifetime.

Quantified Energy Labs Pte. Ltd. · 77 Ayer Rajah Crescent, #03-34, Singapore 139954

Published March 31, 2024

Read the full white paper

Enter your details to unlock the download.